Model Number: 108010
Material: Titanium Alloy TC4
Application:The stub nail is used for internal fixation of femoral intertrochanteric fracture and high subtrochanteric fracture. The long nail is used for internal fixation of low subtrochanteric fracture, femoral trochanteric fracture, femoral trochanter combined ipsilateral femoral shaft fracture, and pathological femoral fracture.
Product Introduction
PFNA (Proximal Femoral Nail Antirotation) Intramedullary Nail is an orthopedic implant system designed primarily for the surgical management of proximal femoral fractures, including intertrochanteric, subtrochanteric, and basilar neck fractures, particularly in osteoporotic patients.
● Penetrates into the femoral head to assist in providing anti-rotation support for the lag screw, reducing the risk of lag screw head cut-out.
● Classic trapezoidal deep-thread design ensures smooth insertion, provides compression to the cancellous bone of the femoral head, and is compatible with patients of various bone qualities.
● Stepped thread design accommodates patients with a narrow femoral neck.
● 5° lateral offset and 1500 mm anterior bow for an optimal match with the physiological anatomy of the Chinese population.
● Optional dynamic or static locking to meet different clinical requirements.
● Distal design disperses stress, reducing pain and the risk of periprosthetic fractures.
1. The intramedullary nail can control the axial force line of the fracture site; the locking intramedullary nail is more effective in preventing fracture rotation and reduces the risk of intramedullary nail fracture.
2. The closed nailing technique is adopted, with less soft tissue stripping, the fracture site can be left unexposed, and the infection rate of the operation is reduced.
3. The closed nailing retains the fracture hematoma and reduces the damage to the periosteum blood supply. At the same time, the debris generated during the expansion of the medullary can be deposited at the fracture site, which has an autologous bone grafting effect.
4. The intramedullary nail generally does not need to be removed. Even if it needs to be removed, only a small incision is made at the corresponding part of the locking nail and one end of the intramedullary nail.
5. There is a stress dispersion effect between the intramedullary nail and the damaged bone to avoid stress shielding.
Application
● Femoral shaft fracture
● Femoral neck fracture or combined femoral shaft fracture
● Intertrochanteric fracture or combined femoral shaft fracture internal fixation
Specifications
Model Number | Category | Spec.(mm) |
4080102 | Short Nail | 10×180 |
10×200 | ||
11.5×180 | ||
11.5×200 | ||
13×180 | ||
13×200 | ||
Long Nail | 10×300 Left | |
10×320 Left | ||
10×340 Left | ||
10×360 Left | ||
10×380 Left | ||
10×400 Left | ||
10×420 Left | ||
11.5×260 Left | ||
11.5×300 Left | ||
11.5×320 Left | ||
11.5×340 Left | ||
11.5×360 Left | ||
11.5×380 Left | ||
11.5×400 Left | ||
11.5×420 Left | ||
13×300 Left | ||
13×320 Left | ||
13×340 Left | ||
13×360 Left | ||
13×380 Left | ||
13×400 Left | ||
13×420 Left | ||
10×300 Right | ||
10×320 Right | ||
10×340 Right | ||
10×360 Right | ||
10×380 Right | ||
10×400 Right | ||
10×420 Right | ||
11.5×260 Right | ||
11.5×300 Right | ||
11.5×320 Right | ||
11.5×340 Right | ||
11.5×360 Right | ||
11.5×380 Right | ||
11.5×400 Right | ||
11.5×420 Right | ||
13×300 Right | ||
13×320 Right | ||
13×340 Right | ||
13×360 Right | ||
13×380 Right | ||
13×400 Right | ||
13×420 Right |
FAQ
Q Are you a factory or a trading company?
We are a manufacturer with factories in different regions across China.
Q What payment methods do you accept?
We accept bank transfer, Western Union, PayPal, and L/C.
Q What is the delivery time?
Usually 4-7 days for products in stock; 15-30 days if out of stock, depending on quantity.
Q What shipping methods do you offer?
We support air, sea, and land shipping based on the order and destination.
Q Do you provide free samples?
Yes, samples are available; shipping costs are paid by the customer.
Q Can I order products not listed in your catalog?
Yes, please send us pictures or samples. Delivery time may be longer.
Talk to ATOM orthopedic experts
We offer a full range of quality spine, trauma, joint, and sports medicine products — fast delivery, consistent quality.
Navigation
Navigation
Contact Us
Tel.: +86 157 5731 2305
E-mail: info@atommd.com
Add.: Room 502, 5th Floor, Deyuan Jiuhe Building, No. 10 Hongyan Road, Chaoyang District, Beijing