Nov. 17, 2026
Platelet-rich plasma (PRP) has attracted growing interest in regenerative medicine and orthopedic applications. As research and clinical experience have developed, PRP preparation technology has also evolved, with increasing attention to platelet enrichment, recovery efficiency, component separation, and preparation consistency.
Early PRP preparation methods relied on relatively conventional blood collection and centrifugation procedures. Improvements in separation structures, closed preparation systems, and processing protocols have gradually made PRP preparation more integrated and convenient.
This article reviews the key stages in the development of PRP preparation technology and introduces the design features of the ATOM PRP Preparation System.
Early PRP preparation primarily relied on centrifugation to separate the components of autologous whole blood.
After blood collection, the sample was processed under centrifugal force. Differences in the sedimentation characteristics of red blood cells, white blood cells, and platelets allowed the blood components to be separated into different fractions.
However, preparation results could vary depending on several factors:
Centrifugation speed and duration
Blood collection and anticoagulant protocols
Separation and collection techniques
Platelet concentration and recovery
Red blood cell and leukocyte contamination
These factors highlighted the need for more controlled preparation procedures and improved separation designs.

As PRP technology developed, greater attention was given to the quality and consistency of the final platelet-enriched fraction.
Rather than focusing only on platelet concentration, improved preparation methods also considered platelet recovery, leukocyte content, and residual red blood cell contamination.
Several technical considerations became increasingly important:
Platelet Enrichment:The objective is to obtain a platelet concentration higher than the baseline level in whole blood. However, a higher concentration alone does not necessarily indicate better clinical performance.
Platelet Recovery:Platelet recovery describes the proportion of platelets retained in the final PRP preparation relative to the original blood sample. It provides additional information about the efficiency of the separation process.
Component Separation:Improved separation structures aim to collect the platelet-enriched fraction while reducing unwanted red blood cell or leukocyte contamination, according to the intended PRP formulation.
Processing Consistency:More clearly defined collection procedures and centrifugation protocols can help reduce variation between preparation cycles.
The evolution of PRP preparation technology can be understood through changes in platelet enrichment, concentration stability, separation procedures, processing time, red blood cell removal, and leukocyte control.
The following table presents a four-generation quality-control classification, illustrating how PRP preparation systems have developed from basic separation tubes toward more integrated systems with improved control over blood component separation.
| Comparison of Four Generations of PRP Preparation Technology | ||||
| Quality-Control Parameter | First Generation | Second Generation | Third Generation | Fourth Generation |
| Platelet Enrichment | <2.5× | <2.5× | >3× | >4× |
| Concentration Stability | Unstable | Stable | Unstable | Stable |
| Number of Separation Cycles | 1 or 2 | 1 | 2 | 1 |
| Separation Time | >30 min | Approximately 15 min | >30 min | Approximately 12 min |
| Residual Red Blood Cells | Usually >5% | <1% | >2% | <1% |
| Leukocyte Control | Very limited adjustability | Leukocyte-poor or leukocyte-free | Leukocyte-rich | Adjustable according to requirements |
| Representative Product Type | Simple tube | Separation gel tube | Three-chamber tube | Two-chamber tube |
Note: This table presents the four-generation classification and performance ranges shown in the supplied reference. It should be understood as a comparative technical framework rather than a universally standardized international classification. Actual performance varies according to product design, blood characteristics, centrifugation protocols, and measurement methods.

A further development in PRP technology has been the integration of blood collection, centrifugation, component separation, and PRP collection into dedicated preparation systems.
Compared with manually coordinated procedures, an integrated system can provide a more organized preparation workflow.
Important design considerations include:
Sealed preparation structure: Supports controlled handling of the blood sample during processing.
Dedicated separation chambers: Help distinguish the platelet-enriched fraction from other blood components.
Simplified operation: Designed to make the preparation process more convenient.
Defined processing protocols: Support repeatable operation when the specified procedure is followed.
Optimized collection structure: Designed to facilitate collection of the target platelet-enriched fraction.
These developments reflect a broader direction in PRP technology: moving from basic blood separation toward more integrated and protocol-based preparation solutions.
A closed or sealed design may support controlled handling, but it does not independently guarantee sterility. Appropriate aseptic procedures and product instructions remain essential.
Modern PRP preparation systems are increasingly evaluated through several performance indicators rather than platelet concentration alone.
| Performance Indicator | Technical Significance |
| Platelet Enrichment Factor | Indicates how much the platelet concentration increases compared with baseline whole blood |
| Platelet Recovery Rate | Indicates the proportion of platelets recovered in the final preparation |
| PRP Yield | Refers to the volume of the final platelet-enriched preparation |
| Blood Component Separation | Relates to the separation of platelets, leukocytes, and red blood cells |
| Processing Time | Reflects the time required for the specified preparation protocol |
These parameters should be considered together. The ideal PRP formulation depends on the intended application, and no single performance indicator can fully determine the biological or clinical quality of PRP.
It is also important to distinguish between laboratory performance data and clinical outcomes. A higher platelet enrichment factor does not automatically establish superior treatment results.
The ATOM PRP Preparation System is designed to isolate platelet concentrates from autologous whole blood through centrifugation.
Its structural design focuses on platelet enrichment, component separation, and convenient preparation.
According to the official product information, the system offers two configurations: Regen-R (Regular) and Regen-B (Bio-engineered).
Key Design Features
1. Integrated Preparation Structure: The system combines blood collection and component separation within a dedicated preparation structure, supporting an organized PRP processing workflow.
2. Platelet Enrichment and Recovery: The product is designed to concentrate platelets in the designated collection section. Its published specifications include a platelet enrichment factor of 4–6× and a platelet recovery rate of at least 80%.
3. Component Separation: The lower chamber is designed to separate the red blood cell fraction, helping minimize unwanted contamination during PRP collection.
4. Sealed Design: The preparation structure features a sealed design intended to support controlled sample handling during processing.
5. Two Preparation Configurations: Regen-R and Regen-B provide different specified centrifugation times while sharing the listed blood collection volume, PRP yield, platelet enrichment factor, and recovery rate.
| Performance Specifications | ||
| Specification | Regen-R (Regular) | Regen-B (Bio-engineered) |
| Blood Collection Volume | 25-30 mL | 25-30 mL |
| PRP Yield /Volume | 3-5 mL | 3-5 mL |
| Platelet Enrichment Factor | 4-6x | 4-6x |
| Platelet Recovery Rate | ≥80% | ≥80% |
| Centrifugation Protocol | Double spin, 8 min | Double spin, 6 min |
Note: Specifications are based on the ATOM product page. Actual preparation results may vary depending on blood characteristics, equipment settings, and operating conditions. Please refer to the current instructions for use for the complete preparation protocol
PRP technology continues to develop, with increasing attention to preparation consistency, product characterization, and application-specific formulations.
Potential areas of continued development include:
More controlled platelet enrichment and recovery
Improved separation of blood components
More standardized preparation protocols
Simplified and integrated processing systems
Better characterization of platelet and leukocyte content
Application-specific PRP formulations
As research progresses, the evaluation of PRP systems is likely to place greater emphasis on both preparation performance and the biological characteristics of the final product.
The development of PRP preparation technology reflects a gradual shift from conventional centrifugation procedures toward more integrated systems designed to improve component separation, platelet enrichment, recovery, and processing convenience.
The ATOM PRP Preparation System offers Regen-R and Regen-B configurations, with published specifications including a 4–6× platelet enrichment factor, a platelet recovery rate of at least 80%, and a PRP yield of 3–5 mL.
By combining a dedicated separation structure with defined preparation configurations, the system provides an option for professional users seeking an integrated PRP preparation solution.
Related Products
Talk to ATOM orthopedic experts
We offer a full range of quality spine, trauma, joint, and sports medicine products — fast delivery, consistent quality.
Navigation
Navigation
Contact Us
Tel.: +86 157 5731 9513
E-mail: info@atommd.com
Add.: Room 502, 5th Floor, Deyuan Jiuhe Building, No. 10 Hongyan Road, Chaoyang District, Beijing